50mm spacing NDT Testing Equipment / Rebar Corrosion Tester 0-300 kΩcm

Certification
China Beijing Samyon Instruments Co., Ltd. certification
China Beijing Samyon Instruments Co., Ltd. certification
I'm Online Chat Now

50mm spacing NDT Testing Equipment / Rebar Corrosion Tester 0-300 kΩcm

Product Details:
Place of Origin: CN
Brand Name: SAMYON
Certification: ISO
Model Number: SY-R72
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: can be negotiated
Packaging Details: carton
Delivery Time: 3-5days
Payment Terms: D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 999/mth

50mm spacing NDT Testing Equipment / Rebar Corrosion Tester 0-300 kΩcm

Description
Name: Steel Bar Corrosion And Resistivity Tester Standard: GB 50204-2015
Corrosion Range: +/- 2000mV Accuracy: +/- 1mV
Test Point Space: 1 ~99cm Test Range: 0 ~ 300 KΩ Cm
High Light:

50mm NDT Testing Equipment

,

Rebar Corrosion NDT Testing Equipment

,

300 KΩcm Rebar Corrosion Tester

SY-R72 Rebar Corrosion And Concrete Resistivity Tester By Electrochemical Method And By Wenner Sensor Array (50mm Space)

 

SY-R72 Rebar corrosion and concrete resistivity tester

 

Application: used to test the degree of steel-bar corrosion by electrochemical method, and to test concrete resistivity by Wenner sensor array (50 mm spacing)

 

Standard:

GB 50204-2015 Code for quality acceptance of concrete structure construction

GB/T 50344 -2004 Technical standard for inspection of building structure

JGJ/T 152-2008 Technical specification for test of reinforcing steel bar in concrete

 

Parameters:

 

Item Name Details
1 Corrosion Test range +/- 2000mV
2 Accuracy +/- 1mV
3 Test point space 1 ~99cm
4 Test range 0 ~ 300 kΩ cm and 0 ~ 3000 kΩ cm
5 Accuracy +/- 1 kΩ cm
6 Display resolution: 0.1 kΩ cm
7 Wenner sensor array 50mm space
7 Power 6pcs No. 5 battery
8 Operating temperature -4°C ~ +40°C
9 Humidity < 90%RH
10 Environment no Strong electromagnetic field
11 Humidity < 90%RH

 

Features:

1. Two test modes: The potentiometry and gradient method is used to test steel-bar corrosion which suitable for different working field.

2. Permanent reference electrode: Saturated CuSO4 solution is sealed up completely in reference electrode. Field test keeps clean, simple and pollution-free operations.

3. Automatic measure environmental temperature. Instrument is with a environmental temperature module, it can measure, record and display temperature quickly, no need thermometers.

4. Can save test date. Convenient for data management.

5. Display test result intuitively by icon mode, The icon color is more dark, the steel-bar corrosion is more serious. User can observe the corrosion degree intuitively.

6. USB transmission. Data can be transmitted to computer for future process and analysis.

7. Powerful data process and analysis software, test data can be exported to word or excel for future process and analysis.

 

 

 

 