Product Details:
|
Name: | Pullout Tester | Standard: | ASTM C900 |
---|---|---|---|
Pullout Force: | 60 + 10% KN | Strength Range: | 5 ~ 80Mpa |
Accuracy: | 1.5% F.S | Effective Area: | 25.13 Cm2 |
High Light: | ASTM C900 Force Test Equipment,80Mpa Force Test Equipment,60KN Pull Out Test Machine |
SY-BCY 60KN Concrete Strength Pullout Tester By Cast-In-Place Method And Post-Install Method
BCY-II 60KN Concrete Strength Pullout Tester
Application:
Used to test the concrete strength of all kinds of existing buildings under 80Mpa by pullout method, to evaluate compressive strength and determine the actual component strength. It can do two testing method as cast-in-place method, and post-instal method.
Standard:
ASTM C900-15 Standard Test Method for Pullout Strength of Hardened Concrete
GB 50367-2013 Code for design of strengthening concrete structure
JGJ 145-2013 Technical specification for post-installed fastenings in concrete structures
Parameters:
Item | Name | Details |
1 | Allowed maximum pullout force | 60 + 10% kN |
2 | Compressive strength range |
5 ~ 80Mpa (cast-in-place method) 5 ~ 80Mpa (post-install method) |
3 | Accuracy | 1.5% F.S (sensor error 0.5%) |
4 | Work cylinder piston effective area | 25.13 cm2 |
5 | Work rod piston stroke | 4 mm |
6 | Pullout tester display error: +/- 2% F.S | +/- 2% F.S |
7 |
Weight:
|
5kg |
8 | Driller and cutter speed | 9500 r/min |
Features:
1. Used to control the construction quality and schedule: to evaluate the influence of concrete transportation, pumping, pouring, compaction and maintenance to cover strength.
2. Decide the appropriate time to dismantle templates, to add load, and to do the hot and humid maintenance in the construction.
3. Test the concrete strength of all kinds of existing buildings under 80Mpa, to evaluate compressive strength and determine the actual component strength.
4. The test will do by cast-in-place method and post-install method
Contact Person: Wendy Lee
Tel: +86 18500992119