Product Details:
|
Name: | Climate Incubator | Temp Control Range: | 0-50℃ |
---|---|---|---|
Standard Layers: | 3blocks | Studio Size: | 1300*620*1300mm |
Power: | 2100W | Illuminance: | 5000LUX |
High Light: | Artificial Climate Incubator,1200L Climate Incubator,2100W Climate Incubator |
1200L Artificial Climate Incubator For Plant Growth And Tissue Culture And BOD Determination
Artificial climate incubator for plant growth and tissue culture
Application:
It is widely used for plant growth and tissue culture, seed Germination, seedling raising, microbial culture test, rearing of insects and small animals, BOD determination of water quality monitoring, aging and service life test of medicinal materials, timber and building materials, etc. The control system has the functions of sound and light alarm, automatic interruption of operation due to exceeding the set high temperature range, and self-protection such as power failure and power recovery to protect the safety of samples and experimental environment. With the light Illuminance 5000lux, the temperature control range will be from 0 to 50℃(No Light 0 ~ 50 °C, with Light 10 ~ 50 °C)
Parameters:
Model number |
SYLC- P160A |
SYLC- P250A |
SYLC- P280A |
SYLC- P380A |
SYLC- P500A |
SYLC- P800A |
SYLC- P1000A |
SYLC- P1200A |
SYLC- P1500A |
Volume L | 160L | 250L | 300L | 400L | 500L | 800L | 1000L | 1200L | 1500L |
Standard Panel | 2Block | 3Block | |||||||
Power supply | AC220V 50HZ | ||||||||
Temperature control range | 0-50℃(No Light 0 ~ 50 °C, Light 10 ~ 50 °C) | ||||||||
Temperature resolution | 0.1℃ | ||||||||
Temperature fluctuation | ±1℃(The experimental conditions are no-load, ambient temperature 20 °C, humidity50%RH) | ||||||||
Humidity range | 50-95%RH(Temperature setting is above 10 degrees, humidity setting is valid) | ||||||||
Moisture control fluctuation | ±3%RH ~ ±7%RH | ||||||||
Illuminance(lux) | 5000LUX | ||||||||
Working Environment | 10~30°C | ||||||||
Internal material | Mirror stainless steel | ||||||||
External material | COLD-ROLLED STEEL PLATE spraying | ||||||||
Time setting | 0-99 hours, 59 minutes/continuous operation | ||||||||
consumed power | 709W | 945W | 1033W | 1361W | 1405W | 2056W | 2056W | 2100W | 3961W |
Studio size |
450*420 *850 |
540*520 *900 |
540*520 *1200 |
640*620 *1100 |
640*620 *1300 |
1200*620 *1050 |
1200*620 *1200 |
1300*620 *1300 |
1710*550 *1400 |
Contour dimension |
550*580 *1560 |
640*680 *1640 |
640*680 *1790 |
740*780 *1700 |
740*780 *1900 |
1300*780 *1830 |
1300*780 *1830 |
1400*780 *1930 |
1810*690 *1970 |
Features:
1. The shell of the upgraded equipment is sprayed with cold-rolled steel plate and adopts integral sealing heat preservation. The whole structure is beautiful and novel, and at the same time achieves good heat preservation effect. Equipment with no raised overall door handle sheet metal design, the overall level is clear, beautiful and generous.
2. Using the microcomputer full-automatic large screen LCD controller developed by us, with 9 working program groups and each group with 99 program segments control or day and night switching control mode, to meet the maximum user control parameters set.
3. LCD controller with China Standard Time display function, so that the user to grasp the experimental time more convenient and simple. The backlight of the controller can be turned off. Start-up display company information function. If there is a failure, the controller will timely alarm and display in the form of text on the display above.
4. Light-emitting chip lamp suitable for plant growth, semiconductor 2835 specification, light bead wavelength range of 400-780nm, luminous Color Temperature Index: 4500K; To avoid the problem of the difference between the light intensity adjusted by different grades and the actual requirement.
5. The refrigeration unit of the equipment adopts the brand compressor, uses the non-fluorine Environmental Protection Refrigerant; the intellectualized temperature adjustment way, will identify the environmental climate change automatically, will adjust the difference of refrigeration up and down, takes into account the accuracy of temperature control and the energy-saving performance of electricity consumption.
6. In order to achieve more stable experimental results, a specially designed air duct with horizontal and vertical circulation effect is adopted to ensure the uniformity of air flow in each layer of the sample.
7. The equipment is equipped with Air Inlet Control Valve, which can adjust the air circulation in and out of the box manually.
8. The control system has the functions of sound and light alarm, automatic interruption of operation due to exceeding the set high temperature range, and self-protection such as power failure and power recovery to protect the safety of samples and experimental environment.
9. External use of large-volume water tank of ultrasonic humidifier humidification, humidification reliable, more stable.
Contact Person: Wendy Lee
Tel: +86 18500992119