Product Details:
|
Name: | Artificial Climate Incubator | Temperature Control Range: | -10 To 50℃ |
---|---|---|---|
Studio Dimension: | 1300*620*1300mm | Illuminance: | 5000LUX |
Inner Capacity: | 160L-1500L | Temperature Accuracy: | 0.1℃ |
High Light: | 5000LUX Biochemical Incubator,1200L Biochemical Incubator,Artificial Climate Incubator |
1200L Low Temperature Artificial Climate Incubator With 50% - 95%RH Humidity
Low temperature artificial climate incubator
Application:
It is widely used for plant growth and tissue culture, seed Germination, seedling raising, microbial culture test, rearing of insects and small animals, BOD determination of water quality monitoring, aging and service life test of medicinal materials, timber and building materials, etc. The microcomputer full-automatic large screen LCD controller is with 9 working program groups and each group with 99 program segments, with day and night switching control mode, to meet the user control parameters set. With different studio size, it can be suitable for different working. The chamber size will be from 160L to 1500L.
Parameters:
Model number |
SYGC- P160A |
SYGC- P250A |
SYGC- P280A |
SYGC- P380A |
SYGC- P500A |
SYGC- P800A |
SYGC- P1000A |
SYGC- P1200A |
SYGC- P1500A |
Volume L | 160L | 250L | 300L | 400L | 500L | 800L | 1000L | 1200L | 1500L |
Standard Panel | 2Block | 3Block | |||||||
Power supply | AC220V 50HZ | ||||||||
Temperature control range | -10-50℃ | ||||||||
Temperature resolution | 0.1℃ | ||||||||
Temperature fluctuation | ±1℃(The experimental conditions are no-load, ambient temperature 20 °C, humidity50%RH) | ||||||||
Humidity range | 50-95%RH(Temperature setting is above 10 degrees, humidity setting is valid) | ||||||||
Moisture control fluctuation | ±3%RH ~ ±7%RH | ||||||||
Illuminance(lux) | 5000LUX | ||||||||
Working Environment | 10~30°C | ||||||||
Internal material | Mirror stainless steel | ||||||||
External material | COLD-ROLLED STEEL PLATE spraying | ||||||||
Time setting | 0-99 hours, 59 minutes/continuous operation | ||||||||
consumed power | 1017W | 1231W | 1253W | 1257W | 1515W | 2430W | 2430W | 2782W | 4269W |
Studio size |
450*420 *850 |
540*520 *900 |
540*520 *1200 |
640*620 *1100 |
640*620 *1300 |
1200*620 *1050 |
1200*620 *1200 |
1300*620 *1300 |
1710*550 *1400 |
Contour dimension |
550*580 *1560 |
640*680 *1640 |
640*680 *1790 |
740*780 *1700 |
740*780 *1900 |
1300*780 *1830 |
1300*780 *1830 |
1400*780 *1930 |
1810*690 *1970 |
Features:
1. The shell is sprayed with cold-rolled steel plate and adopts integral sealing heat preservation. The whole structure is beautiful and novel, and at the same time achieves good heat preservation effect. .
2. The microcomputer LCD controller is with 9 working program groups for day and night switching control mode.
3. LCD controller with China Standard Time display function, so that the user to grasp the experimental time more convenient and simple. The backlight of the controller can be turned off. Start-up display company information function. If there is a failure, the controller will timely alarm and display in the form of text on the display above.
4. Light-emitting chip lamp is to avoid the problem of the difference between the light intensity adjusted by different grades and the actual requirement.
5. Automatic frost-free running mode combined with energy-free defrosting mode can effectively avoid large temperature fluctuations and affect the experimental results, and ensure the temperature stability of the equipment for a long time.
6. The refrigeration uses the non-fluorine Environmental Protection Refrigerant.
7. In order to achieve more stable experimental results, a specially designed air duct with horizontal and vertical circulation effect is adopted to ensure the uniformity of air flow in each layer of the sample.
8. The equipment is equipped with Air Inlet Control Valve, which can adjust the air circulation in and out of the box manually.
9. The control system has the functions of sound and light alarm, automatic interruption of operation due to exceeding the set high temperature range, and self-protection such as power failure and power recovery to protect the safety of samples and experimental environment.
10. External use of large-volume water tank of ultrasonic humidifier humidification, humidification reliable, more stable
Contact Person: Wendy Lee
Tel: +86 18500992119