Product Details:
|
Name: | Mold Curing Box | Temperature Control Range: | 0-50℃ |
---|---|---|---|
Standard Panel: | 2blocks Or 3 Blocks | Humidity Range: | 50%-95%RH |
Inner Chamber: | 80L To 1500L | Temperature Error: | +/-1 |
High Light: | SYJT Biochemical Incubator,400L Biochemical Incubator,3 Blocks Mold Incubator |
SYJT 80L To 1500L Mold Incubator For Incubating Bacteria And Mold Under Constant Temperature And Humidity
Mold incubator for environmental protection, health and epidemic prevention
Application:
It is used for environmental protection, health and epidemic prevention, drug testing, agricultural and livestock, aquatic products and other scientific research. It is used for the water analysis and Bod determination, bacteria, mold, microbial culture, conservation, plant cultivation, breeding test dedicated constant temperature equipment. The temperature control range will be from 0 to 50℃ with high precision temperature controller and probes. And the humidity will be controlled from 50% to 95%RH. The inside plate takes mirror stainless steel, so it can avoid corrosion after long time usage with high humidity.
Parameters:
Model number |
SYJT- P80C |
SYJT- P150C |
SYJT- P250C |
SYJT- P290C |
SYJT- P400C |
SYJT- P500C |
SYJT- P800C |
SYJT- P1000C |
SYJT- P1200C |
SYJT- P1500C |
Volume L | 80L | 150L | 250L | 300L | 400L | 500L | 800L | 1000L | 1200L | 1500L |
Standard Panel | 2Block | 3Block | ||||||||
Power supply | AC220V 50HZ | |||||||||
Temperature control range | 0-50℃ | |||||||||
Humidity range | 50-95%RH(Temperature setting is above 10 degrees, humidity setting is valid) | |||||||||
Temperature resolution | 0.1℃ | |||||||||
Temperature fluctuation | ±1℃(The experimental conditions are no-load, ambient temperature 20 °C, humidity50%RH) | |||||||||
Moisture control fluctuation | ±3~±7%RH | |||||||||
Working Environment | 10~30°C | |||||||||
Internal material | Mirror stainless steel | |||||||||
External material | COLD-ROLLED STEEL PLATE spraying | |||||||||
Time setting | 0-99 hours, 59 minutes/continuous operation | |||||||||
consumed power | 316W | 547W | 585W | 754W | 1532W | 1048W | 1532W | 1532W | 1532W | 2532W |
Studio size |
450*420 *450 |
450*420 *850 |
540*520 *900 |
540*520 *1200 |
640*620 *1100 |
640*620 *1300 |
1050*600 *1200 |
1200*600 *1200 |
1300*600 *1300 |
1710*550 *1400 |
Contour dimension |
550*580 *1080 |
550*580 *1560 |
640*680 *1640 |
640*620 *1790 |
740*780 *1700 |
740*780 *1900 |
1300*780 *1830 |
1300*780 *1830 |
1400*780 *1930 |
1810*690 *1970 |
Features:
1. The shell adopts integral sealing heat preservation. The system is with no raised overall door handle sheet metal design, the overall level is clear, beautiful and generous.
2. The full-automatic large screen LCD controller is with 9 working program groups switching control mode, to meet the user control parameters setting .
3. The backlight of the controller can be turned off. If there is a failure, the controller will timely alarm.
4. The refrigeration uses the non-fluorine Environmental Protection Refrigerant.
5. The horizontal and vertical three-dimensional breeze circulation can ensure the air flow uniformity of each layer, so as to control the more stable experimental results.
6. Equipped with Air Inlet Control Valve, the air circulation inside and outside the box can be adjusted by manual switch.
7. The self-protection function of the control system can automatically interrupt the operation when it exceeds the set high temperature range, sound and light alarm, and protect the safety of the sample and the experimental environment.
8. The control system has the function of restoring power due to power failure. If there is a failure, the controller will timely alarm.
Contact Person: Wendy Lee
Tel: +86 18500992119